Software:Neuberger PMC-Software
Description
PMC is a DOS-based program for building automation purpose developed by Neuberger Gebäudeautomation in Rothenburg/BY/Germany. If there are problems with serial connections under Windows - use DOSBOX and it rocks!
Status
Tested with DosBox 0.70 (under Windows 2000 / XP). The program runs and all functions work. If you have trouble with usb-serial-adapters, use adapters with Prolific chipset and latest drivers. This is, what the developer has used for his tests. Current should work too.
Making it to work
Sample dosbox.conf for COM1: using the default software installation folder D:\ProGrafNT\PMC:
Dosbox.conf start
[sdl]
fullscreen=false fulldouble=false fullresolution=original windowresolution=original output=surface autolock=false sensitivity=100 waitonerror=true priority=higher,normal mapperfile=mapper.txt usescancodes=true
[dosbox]
language= machine=vga captures=capture memsize=16
[render]
frameskip=0 aspect=true scaler=normal2x
[cpu]
core=normal cycles=3000 cycleup=500 cycledown=20
[mixer]
nosound=false rate=22050 blocksize=2048 prebuffer=10
[midi]
mpu401=intelligent device=default config=
[sblaster]
sbtype=sb16 sbbase=220 irq=7 dma=1 hdma=5 mixer=true oplmode=auto oplrate=22050
[gus]
gus=true gusrate=22050 gusbase=240 irq1=5 irq2=5 dma1=3 dma2=3 ultradir=C:\ULTRASND
[speaker]
pcspeaker=true pcrate=22050 tandy=auto tandyrate=22050 disney=true
[bios]
joysticktype=2axis
[serial]
serial1=directserial realport:com1 startbps:19600 parity:n bytesize:8 stopbits:1 irq:4 serial2=dummy serial3=disabled serial4=disabled
[dos]
xms=true ems=true umb=true
[ipx]
ipx=false
[autoexec]
cls mount a a:\ mount c c:\ mount d d:\ d: cd \prografnt\pmc pmc exit Dosbox.conf End ----
Versions
- Versions from 2.11.2 to 2.14.5 worked